| • AT-60, 90 |
 |
| • AT-120, 180, 190 |
 |
| • AT-240, 300 |
 |
| • WT-60, 90 |
 |
| • WT-120, 180, 190 |
 |
| • WT-240, 360 |
 |
| • OAT-60, 90 |
 |
| • OAT-120, 180 |
 |
| • OAT-240, 300 |
 |
| • WAT-60, 90 |
 |
| • WAT-120, 180 |
 |
| • WAT-240, 300 |
 |
| • AH |
 |
| • AH-2 |
 |
| •
WH |
 |
| • WH-2 |
 |
| • WDC-90, 150, 300 |
 |
| |
| |
|
|
|
| |
Heat Pump Water Heater -
WH-100P , WH-200P , WH-300P ,
WH-400P |
|
|
MODEL :
WH-100P~WH400P / WM-120P~WM-600P
WH-65P2 ~400P2 / WM-100P2~WM-600P2 |
 |
 |
|
Specification : |
| PRODUCTS |
WH-100P |
WH-200P |
WH-300P |
WH-400P |
| Air temp. range |
5°C~45°C |
| Water temp. range |
60°C~65°C |
| Min input water temp. |
8°C |
| Power |
3P-220 /
380V-50/60HZ |
| Coolant |
R134a / R407 |
| Liquid |
Tap water |
Heating capacity
|
Btu-h |
80,400/
100,500 |
159,200/
199,000 |
252,000/
315,000 |
313,600/
392,000 |
| Kcal-h |
20,300/
25,350 |
40,100/
50,150 |
63,500/
79,400 |
79,000/
98,740 |
| kW |
24 / 29.5 |
47/ 58.5 |
74 / 92.5 |
92/115 |
| Cooling capacity |
Btu-h |
57,600 /
72,000 |
114,400 /
143,000 |
184,000 /
230,000 |
228,000 /
285,000 |
| Outlet temp. accuracy |
±1°C |
| Hot water flow |
25 GPM |
45 GPM |
75 GPM |
95 GPM |
| Power circuit |
No fuse breaker, inverse/reverse phase, ultra high/low temp., external air, overload protection |
| Control mode |
Microprocessor |
| Power consumption (kW) |
8 / 10 |
16 / 19 |
25 / 30 |
31 / 37 |
| Coolant system |
upper/lower voltage |
| Hot water inlet / inlet |
1-1/2" |
2" |
2-1/2"" |
| Cold water inlet / outlet |
1" |
1-1/2" |
2" |
| L x W x H (mm) |
1,300x900x1,760 |
1,760x1,050x1,980 |
| Weight (kg) |
520 |
965 |
1,250 |
1,600 |
|
| PRODUCTS |
WM-120P |
WM-200P |
WM-300P |
WM-400P |
WM-600P |
| Air temp. range |
5°C~45°C |
| Water temp. range |
50°C~55°C |
| Min input water temp. |
8°C |
| Power |
3P-220 /
380V-50/60HZ |
| Coolant |
R22 |
| Liquid |
Tap water |
Heating capacity
|
Btu-h |
100,800/
126,000 |
156,800/
196,000 |
252,000/
315,000 |
316,800/
396,000 |
484,000/
605,000 |
| Kcal-h |
25,400/
31,750 |
39,500 /
49,370 |
63,500/
79,350 |
79,800/
99,750 |
122,000/
152,400 |
| kW |
29.5 / 37 |
46 / 57.5 |
74 / 92.5 |
93 / 116 |
142 / 177 |
| Cooling capacity |
Btu-h |
72,600/
90,720 |
113,600/
142,000 |
184,000/
230,000 |
228,000/
285,000 |
368,000/
460,000 |
| Outlet temp. accuracy |
±1°C |
| Hot water flow |
30 GPM |
45 GPM |
75 GPM |
95 GPM |
150 GPM |
| Power circuit |
No fuse breaker, inverse/reverse phase, ultra high/low temp., external air, overload protection |
| Control mode |
Microprocessor |
| Power consumption (kW) |
10 / 11 |
15 / 17 |
25 / 28 |
31 / 35 |
47 / 54 |
| Coolant system |
upper/lower voltage |
| Hot water inlet/outlet |
1-1/2" |
2" |
2-1/2" |
3" |
| Cold water inlet /outlet |
1" |
1-1/2" |
2" |
2-1/2" |
| L x W x H (mm) |
1,300x900x
1,760 |
1,760 x 1,050 x
1,980 |
| Weight (kg) |
520 |
965 |
1,250 |
1,600 |
|
|
| |
| |
|
Relative Product :
Home >
Product Category >
Heat Pump Water Heater >
HA-200, 320 |
| |
|
|